FeaturesHardwareCompatible with the ISO 11898-2 standardCompatible with CAN specification 2.0 A/B and FDCAN FD support for ISO and Non-ISO (Bosch) standards switchableCAN FD bit rates for data field from 100 kbps to 10000 kbpsCAN bit rates from 10 kbps to 1000 kbpsBuilt-in DIP-switch to enable/disable the terminal resistorTwo CAN bus interfaces with 9 pin D-sub connectorSoftwareWeb configurationCAN bus ID filterModbus TCP Server functionTCP/UDP to CAN transparent communicationCAN pair connection via UDP communicationUDP responder for device discoveryStatic IP or DHCP network configurationIntroductionThe IoT (Internet of Things) has been a much discussed topic in recent years. Using the IoT concept, it is easy to integrate the environment of heterogeneous network and let all of the things into be digitized making life more convenient. In order to provide additional access to IoT applications related to industry based on the CAN bus, ICPDAS has developed a new Ethernet product, the ECAN-240-FD. The ECAN-240-FD module is a Modbus TCP to 2-port CAN FD (CAN with Flexible Data-Rate) Gateway. As its functionality, that provides communications via the Ethernet based on the Modbus TCP industrial protocol, meaning that the module can be easily integrated with an industrial network. The ECAN-240-FD module includes two CAN bus interfaces, meaning that more various CAN applications can be supported.LED IndicatorsStatus1 x Power, 3 x CAN1 status, 3 x CAN2 statusEthernetPorts1 x RJ-45, 10/100 Base-TXProtocolModbus TCP, HTTP, BOOTP, TFTPCANPorts2Baud RateCAN bit rates: 10 k 1 M bps,CAN FD bit rates for data field: 100 k 10M bpsIsolation3000 VDC for DC-to-DC, 2500 Vrms for photo-coupleTerminal ResistorDIP switch for the 120 terminal resistorSpecificationISO 11898-2, CAN 2.0 A/B and FDFilterYesPowerInput Range+10 VDC +30 VDCConsumption1.2 WMechanicalCasingMetalDimensions (mm)122.0 x 160.0 x 28.0 (W x L x H)InstallationDIN-RailEnvironmentOperating Temperature-25 +75 CStorage Temperature-30 +80 CHumidity10 90% RH, Non-condensing

FAQs of Modbus TCP to CAN Gateway:


Q: What are the dimensions of the Modbus TCP to CAN Gateway?

A: The dimensions of the Modbus TCP to CAN Gateway are 122.0 x 160.0 x 28.0 millimeters (L x W x H).

Q: What is the power supply requirement for the Modbus TCP to CAN Gateway?

A: The Modbus TCP to CAN Gateway has a power supply requirement of 24VDC and can operate within a range of +10 VDC to +30 VDC.

Q: Is the Modbus TCP to CAN Gateway suitable for industrial usage?

A: Yes, the Modbus TCP to CAN Gateway is designed for industrial usage.

Q: What is the operating storage temperature range for the Modbus TCP to CAN Gateway?

A: The Modbus TCP to CAN Gateway can be stored within a temperature range of -30C to +80C.

Q: What is the weight of the Modbus TCP to CAN Gateway?

A: The Modbus TCP to CAN Gateway weighs 100 grams.