CANopen Gateway
Product Details:
- Product Type CANOpen Mudule
- Storage Temperature -25 ~ +75 Celsius (oC)
- Network Connection Methods Wired
- Power 3 Watt (w)
- Dimension (L*W*H) 72 x 122 x 33 (W x H x D) Millimeter (mm)
- Weight 100 Grams (g)
- Usage Industrial
- Click to View more
CANopen Gateway Price And Quantity
- 10 Piece
CANopen Gateway Product Specifications
- 24VDC
- 100 Grams (g)
- 3 Watt (w)
- -25 ~ +75 Celsius (oC)
- Gray
- Industrial
- CANOpen Mudule
- 72 x 122 x 33 (W x H x D) Millimeter (mm)
- +10 VDC ~ +30 VDC
- Wired
- Plastic
CANopen Gateway Trade Information
- Cheque
- 1000 Piece Per Month
- 4 Days
- Device
- Asia Australia Central America North America South America Eastern Europe Western Europe Middle East Africa
- All India
- CE/FCC/ROHS
Product Description
Features
- NMT: Slave
- Error Control: Node Guarding protocol
- Node ID: Setting by CAN_MRU Utility Software or LSS Protocol
- PDO Modes: Event-triggered, remotely requested, cyclic and acyclic SYNC
- PDO Mapping: variable
- No of SDOs: 1 server, 0 client
- Emergency Message: Yes
- CANopen Version: DS-301 v4.02
- Device Profile: DSP-401 v2.1
- CiA DSP-305 V1.1
- Support max 10 Modbus RTU I/O series modules
- Provide friendly Utility for parameter configuration
- 7-segmemt LED to show Node ID, CAN baud rate and RS-485 baud rate
Introduction
The I-7232D is a CANopen slave to Modbus RTU master gateway, and allows a CANopen master to have ability to access the Modbus slave devices. In the CANopen network, the I-7232D is a NMT slave, SDO server, PDO producer, and PDO consumer. From the view of the Modbus network, it is a Modbus RTU master which polls all the predefi ned data of the Modbus RTU slaves, and bypass the CANopen control commands to the Modbus slaves. The I-7232D follows the CANopen specification CiA-301 v4.02 and CiA-401 v2.1, and supplies many features of CANopen protocols, such as dynamic PDO, EMCY object, error output value, SYNC cyclic and acyclic. Like the I-7231D, the EDS file is also provided by the utility tool. Users can easily apply the I-7232D in the standard CANopen master with the EDS file.
CPU Module | |
---|---|
Watchdog Timer | Hardware watchdog |
LED Indicators | |
---|---|
Status | MS LED, NS LED, IO LED |
COM Ports | |
---|---|
Ports | 1 x RS-232/485, Non-isolated |
Baud Rate | 1200 115200 bps |
Protocol | Modbus RTU Master |
Parity | None, Even, Odd |
Data Bit | 7, 8 |
Stop Bit | 1, 2 |
CANopen | |
---|---|
Controller | NXP SJA1000T with 16 MHz clock |
Ports | 1 |
Baud Rate | 10k 1M |
Isolation | 1000 VDC for DC-to-DC, 2500 Vrms for photo-couple |
Terminal Resistor | Built-in 120Î |
Protocol | CiA 301 v4.02 |
Node ID | 1 255 |
Error Control | Node Guarding protocol/Heartbeat Producer |
NMT | Slave |
EMCY Message | Yes |
Power | |
---|---|
Consumption | 3W |
Mechanical | |
---|---|
Dimensions (mm) | 72 x 122 x 33 (W x H x D) |
Environment | |
---|---|
Operating Temperature | -25 +75 C |
Storage Temperature | -30 +80 C |
Humidity | 10 90% RH, Non-condensing |

Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
Other Products in 'CAN Modules' category
![]() |
NIMBUS TECHNOLOGIES
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |