हमें कॉल करें : 08045812107
BACnet/IP to Modbus TCP Gateway
35400.0 आईएनआर/टुकड़ा
उत्पाद विवरण:
- प्रॉडक्ट टाइप BACnet
- स्टोरेज टेम्परेचर सेल्सियस (oC)
- नेटवर्क कनेक्शन के तरीके Wired
- पावर वाट (w)
- आयाम (एल* डब्ल्यू* एच) मिलीमीटर (mm)
- वज़न ग्राम (g)
- रेंज +10 VDC ~ +30 VDC
- अधिक देखने के लिए क्लिक करें
X
मूल्य और मात्रा
- 1
उत्पाद की विशेषताएं
- +10 VDC ~ +30 VDC
- ग्राम (g)
- 24VDC
- वाट (w)
- BACnet
- सेल्सियस (oC)
- Wired
- Plastic
- मिलीमीटर (mm)
- Black
व्यापार सूचना
- प्रति महीने
- दिन
- Device
- , , , , , , , ,
- CE/FCC/ROHS
उत्पाद वर्णन
FeaturesRead/Write Modbus registers via BACnet objectsConfigurable BACnet/IP ServerConfigurable Modbus TCP ClientSupports BACnet AI, AO, AV, BI, BO, BV, MSI, MSO, MSV Object TypesSupports Modbus discrete inputs, coils, input registers and holding registersSupports up to 180 DI, 180 DO, 180 AI and 180 AO to transfer to BACnet ObjectsSimple data translation allows you to manipulate data as it passes between protocolIntroductionGW-2493M is a network gateway allowing BACnet client devices to be accessed Modbus network as a Modbus TCP client. The BACnet/IP protocol is used to relay and exchange information between building devices. GW-2493M contains a large number of BACnet objects (AI, AO, AV, BI, BO, BV, MSI, MSO, MSV) gives you flexibility in mapping Modbus TCP registers to any combination of BACnet objects. Multiple BIBBs (DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM-B,etc.) are supported. All the data transfer is configurable using a standard Web browser.LED IndicatorsStatusPower (1), BACnet/IP Status (1), BACnet/IP Net(1),Modbus TCP TxD/RxD/Link (3)Ethernet LED Ethernet Status (RJ-45) (2)EthernetPorts1 x RJ-45, 10/100Base-TXBACnet/IPProtocolModbus TCP Client(Supports up to 32 stations)ObjectsAI, AO, AV, BI, BO, BV, MSI, MSO, MSV(Convert modbus 180 DI, 180 DO, 180 AI and 180 AO)BIBBsDS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM-B, DM-DDB-B, DM-DOB-B, DM-DCC-B, DM-RD-BPowerInput Range+10 +30 VDCConsumption5W @ 24VDCMechanicalCasingMetalDimensions (mm)33 x 120 x 116InstallationDIN-RailEnvironmentOperating Temperature-25 +75 CStorage Temperature-30 +80 CHumidity10 90% RH, Non-condensingFAQs of BACnet/IP to Modbus TCP Gateway:
Q: What are the dimensions of the BACnet/IP to Modbus TCP Gateway?
A: The dimensions of the BACnet/IP to Modbus TCP Gateway are 33 x 120 x 116 millimeters (mm).Q: What is the power supply and range supported by the Gateway?
A: The Gateway operates with a 24VDC power supply and supports a range of +10 VDC to +30 VDC.Q: What is the typical power consumption of the Gateway?
A: The Gateway consumes 5W when powered at 24VDC.Q: What kind of network connection method does the Gateway use?
A: The Gateway uses wired network connection methods.Q: What is the storage temperature range for the Gateway?
A: The Gateway can be stored in temperatures ranging from -30C to +80C.Q: What material is used for the Gateways construction?
A: The Gateway is constructed using durable plastic material.Q: What is the weight of the BACnet/IP to Modbus TCP Gateway?
A: The Gateway weighs 200 grams (g).Tell us about your requirement

Price: Â
Quantity
Select Unit
- 50
- 100
- 200
- 250
- 500
- 1000+
Additional detail
मोबाइल number
Email
BACnet Modules अन्य उत्पाद
![]() |
NIMBUS TECHNOLOGIES
सर्वाधिकार सुरक्षित.(उपयोग की शर्तें) इन्फोकॉम नेटवर्क प्राइवेट लिमिटेड . द्वारा विकसित एवं प्रबंधित |